Measurement methods and equipments

    High resolution gamma ray spectrometry
  • Gamma activity measurement installation with HPGe spectrometry system CANBERRA + SILENA
    Characteristics:
    HPGE detector– Silena, model RGC-P1519
    Incorporated preamplifier (cooled) – model RFP 110;
    Shielded enclosure + lead collimator
    AMC – CANBERA – INSPECTOR, type 1200, with incorporated HV bias supply
    Energy range 50 keV – 2049 keV
    Computer TI-Pentium-LAPTOP
    Software GENIE-2000; GAMMA ALALISYS , SPECTROSCOPY ASSISTANT V.2.0/2001;
  • Gamma activity measurement installation with HPGe spectrometry system CANBERRA
    Characteristics:
    HPGe detector– Canberra model GC-2518
    Incorporated preamplifier (cooled), model CSL-2002 110;
    Lead shielded enclosure
    MCA– CANBERA – INSPECTOR, type 1270, with incorporated HV bias supply
    Energy range 30 keV – 1718 keV
    Software GENIE-2000; GAMMA ALALISYS , SPECTROSCOPY ASSISTANT V.2.0/2001;
  • Low background, alpha/beta radiometer,  model MPC 9300, Protean Instrument Corporation
    Characteristics:
    Gas flow proportional counter (P-10 Argon-Methane)
    Window thickness 80 mg/cm2 – ultra low background
    Efficiency for 90Sr-90Y - 55%,
    Efficiency for 241Am - 42%.
    Voltage Range 705V – 1875 V
    Computer compatible MS-DOS/MS Windows
    PICNET Software
    Liquid scintillation beta spectrometry
  • Liquid scintillation analyzer, type Packard, model TRI-CARB 2100 TR
    Characteristics:
    Detectors: 2 photomultiplier tubes
    Energy range: 0 - 2000 keV
    Predefined ranges:
    Tritium: 0-18.6 keV
    Carbon 14: 0-156 keV
    Phosphorus 32: 5-1700 keV
    Iodine 125: 0-70 keV
    Minimum acceptable efficiency:
    Tritium: 60%
    Carbon 14:95%
    Radiation fields direct measurements
  • Portable radiometer/contaminometer, model FH40 GL10
    Characteristics:
    Incorporated GM detector
    FAG probe, model FHZ 120 A
    FAG probe, model FHZ 140
    Energy range 45 keV – 1.3 MeV
    Measuring range 0.01 µSv/h – 9.99mSv/h
  • Hand held radiation measuring device with spectrometric capabilities, InSpector 1000 model,  CANBERRA
    Characteristics:
    NaI detector 1,5 ´ 1,5cc – energy range 50 keV – 3 MeV
    Incorporated GM detector – energy range 30 keV – 1.4 MeV
    Nuclid Identification (NID)  Mode GENIE-2000
    Spectrum storage capacity  > 256 specters
    USB HOST-USB DEVICE
    Radiometry
  • Mobile system for characterization of radioactive materials ISO-Cart Integration and Test Record ORTEC
    Characteristics:
    HPGE detector;
    ISO-Cart versatile transport and manipulation system
    Shielded enclosure + Pb and W collimators
    Turn table option supporting drums with mass up to 450 kg
    Loading and weighing cell
    MCA Model Digi Dart
    Energy range 60 keV – 1840 keV
    Computer LAPTOP Dell Model Latitude D520
    Software ISOTOPIC - 32; Gamma Vision

Dr. Alexandru Toma – head of laboratory
Tel.:
+40 248 213400 ext. 524
Fax.: +40 248 262449
e-mail: alexandru.toma@scn.ro sau altomasandu@yahoo.com

Mr. Hirica Ovidiu – QA responsible
Tel.:
+40 248 213400 ext. 109
Fax.: +40 248 262449
e-mail: ovidiu.hirica@yahoo.com

Dr. Cristian Dulama
Tel.:
+40 248 213400 ext. 511
Fax.: +40 248 262449
e-mail: cristian.dulama@scn.ro sau cdulama@gmail.com

Mr. Relu Dobrin
Tel.:
+40 248 213400 ext. 511
Fax.: +40 248 262449
e-mail: relu.dobrin@gmail.com